測試儀Mach-1應用:壓痕小鼠股骨軟骨剛度和顳下頜關節(jié)下頜軟骨改變

來源:世聯博研(北京)科技有限公司   2021年03月18日 15:37  

Biomomentum多軸機械測試儀Mach-1應用:

Automated Indentation Demonstrates Structural Stiffness of Femoral Articular Cartilage and Temporomandibular Joint Mandibular Condylar Cartilage Is Altered in FgF2KO Mice

Paige S. Woods, Alyssa A. Morin, Po-Jung Chen, Sarah Mahonski, Liping Xiao, Marja Hurley, Sumit Yadav, and Tannin A. Schmidt

CARTILAGE. October 2020. doi:10.1177/1947603520962565

Objective

Employ an automated indentation technique, using a commercially available machine, to assess the effect of fibroblast growth factor 2 (FGF2) expression on structural stiffness over the surface of both murine femoral articular cartilage (AC) and temporomandibular joint (TMJ) mandibular condylar cartilage (MCC).

 

Design

Experiments were performed using 3-month-old female homozygote Fgf2KO mice with wild type (WT) littermates. After euthanization, isolated mandibles and hindlimbs were either processed for histology or subjected to automated indentation on a Biomomentum Mach-1 v500csst with a 3-axis motion controller in a phosphate buffered saline bath using a 0.3 mm spherical tip indenter. The effect of indentation depth on normal force was characterized, then structural stiffness was calculated and mapped at multiple positions on the AC and MCC.

Results

Automated indentation of the AC and TMJ MCC was successfully completed and was able to demonstrate both regional variation in structural stiffness and differences between WT and Fgf2KO mice. Structural stiffness values for Fgf2KO AC were significantly smaller than WT at both the medial/anterior (P < 0.05) and medial/posterior (P < 0.05) positions. Global Fgf2KO also lead to a decrease in MCC thickness of the TMJ compared with WT (P < 0.05) and increased structural stiffness values for Fgf2KO at both the posterior and anterior location (P < 0.05).

 

Conclusions

Biomomentum多軸機械測試儀Mach-1應用:自動壓痕表明FgF2KO小鼠股骨軟骨的結構剛度和顳下頜關節(jié)下頜Con突軟骨發(fā)生改變。

采用自動壓痕技術,使用市售機器評估成纖維細胞生長因子2(FGF2)表達對鼠股骨關節(jié)軟骨(AC)和顳下頜關節(jié)(TMJ)下頜con突軟骨表面的結構剛度的影響(我的客戶中心(MCC)。設計使用具有野生型(WT)同窩仔的3個月大的雌性純合子Fgf2KO小鼠進行實驗。對分離出的下頜骨和后肢進行組織學處理,或在帶有3-軸運動控制器的Biomomentum Mach-1 v500csst上使用0.3毫米球形尖壓頭在磷酸鹽緩沖鹽水浴中進行自動壓痕。表征了壓痕深度對法向力的影響,然后計算結構剛度并將其映射到AC和MCC的多個位置。結果AC和TMJ MCC的自動壓痕已成功完成,并且能夠證明結構剛度的區(qū)域差異以及WT和Fgf2KO小鼠之間的差異。Fgf2KO AC的結構剛度值在內側/前側(P <0.05)和內側/后側(P <0.05)位置均顯著小于WT。與WT相比,整體Fgf2KO還會導致TMJ的MCC厚度減?。≒ <0.05),并且在后部和前部位置的Fgf2KO的結構剛度值都會增加(P <0.05)。

免責聲明

  • 凡本網注明“來源:化工儀器網”的所有作品,均為浙江興旺寶明通網絡有限公司-化工儀器網合法擁有版權或有權使用的作品,未經本網授權不得轉載、摘編或利用其它方式使用上述作品。已經本網授權使用作品的,應在授權范圍內使用,并注明“來源:化工儀器網”。違反上述聲明者,本網將追究其相關法律責任。
  • 本網轉載并注明自其他來源(非化工儀器網)的作品,目的在于傳遞更多信息,并不代表本網贊同其觀點和對其真實性負責,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網站或個人從本網轉載時,必須保留本網注明的作品第一來源,并自負版權等法律責任。
  • 如涉及作品內容、版權等問題,請在作品發(fā)表之日起一周內與本網聯系,否則視為放棄相關權利。
企業(yè)未開通此功能
詳詢客服 : 0571-87858618
武功县| 延庆县| 石阡县| 建湖县| 兖州市| 古丈县| 诏安县| 儋州市| 乌鲁木齐市| 景泰县| 霞浦县| 禄丰县| 泾阳县| 拜泉县| 漯河市| 沙坪坝区| 定结县| 呼伦贝尔市| 礼泉县| 万山特区| 神木县| 丘北县| 武冈市| 章丘市| 财经| 西安市| 石首市| 奉新县| 石景山区| 紫金县| 广丰县| 普洱| 黄浦区| 凤翔县| 沈阳市| 嘉荫县| 彝良县| 南和县| 邹平县| 潮州市| 嵩明县|