北美糾偏H6600-SW-01功能介紹
點(diǎn)擊次數(shù):1311 發(fā)布時(shí)間:2015-8-14
北美糾偏H6600-SW-01功能介紹
北美糾偏控制器型號(hào):(加“/ 2"作為suffi x可為220伏交流電操作)
北美糾偏控制器H6600-BFR-01標(biāo)準(zhǔn)模型
北美糾偏控制器H6600-BFR-02手動(dòng)/自動(dòng)開關(guān)和輸入 - 輸出春中心交換機(jī)
北美糾偏控制器H6600-BFR-03同02,與蓋加偏移鍋
北美糾偏控制器H6600-BFR-04手動(dòng)/自動(dòng)/伺服中心交換機(jī)和輸入 - 輸出中心交換機(jī)上封面
北美糾偏控制器H6600-BFR-05同04與封面上的偏移鍋
北美糾偏控制器H6600-SS-01自尋道電機(jī)驅(qū)動(dòng)輸出
北美糾偏控制器H6600-SW-01 Staggerwind控制
北美糾偏控制器H6600-SSSW-01自尋道電機(jī)驅(qū)動(dòng)器staggerwind
北美糾偏控制器電源要求:102-132或204-264伏交流50-60赫茲(zui大)。
北美糾偏控制器輸出:直線電機(jī)驅(qū)動(dòng)(±125毫安)
遠(yuǎn)程抄表驅(qū)動(dòng)器(±10 V DC)
“C"電磁驅(qū)動(dòng)器,NO和NC觸點(diǎn)(264 V AC,zui大)。
北美糾偏控制器報(bào)警繼電器,常開觸點(diǎn)(264V AC,2Azui大。)
北美糾偏控制器技術(shù)規(guī)格
輸入端口:兩個(gè)獨(dú)立的探測器輸入(高達(dá)±15 V DC)
側(cè)傾中心/位置反饋(±15 V DC)
遠(yuǎn)程條偏移電位(±15 V直流和±5 V DC)
工作溫度范圍:32-122°F(0-50℃)
交流輸入:啟用
自動(dòng)/手動(dòng)
手冊慢跑
手動(dòng)點(diǎn)動(dòng)OUT
側(cè)傾中心
電池備份的存儲(chǔ)器:壽命:11年以上。
選項(xiàng)??:Staggerwind選項(xiàng)將接受編碼器輸入和
錯(cuò)開的Guidepoint在用戶選擇的速率和幅度。
自謀選項(xiàng)將通過提供自動(dòng)或手動(dòng)探測器定位
額外的AC輸入。
北美糾偏控制器外形尺寸:12 1/4“寬x 16"高x 4 1/2“D(311毫米×406毫米×114毫米)
北美糾偏控制器重量:17磅(8公斤)
Microprocessor-based
Simplifi ed, menu-driven setup
Adaptable inputs accept wide range of
transducers
Alarm output for system faults
Remote offset capability
Bar graph meter indicates position of
material in detector or amplifi er
output voltage.
The microprocessor-based H6600 series of electronic controllers provides all functions necessary to accommodate a wide range
of guiding applications, while maintaining a simple, menu-driven, set-up. It accepts all of Fives North American's detectors: edge
guide, center-guide, ultrasonic and roll center, plus most off-the-shelf transducers. The controller will directly drive an electro-
hydraulic servo valve or the input of a power amplifi er for electro-mechanical applications.
The H6600's microprocessor simplifi es setup by confi guring the detector inputs based on menu selections from the front panel.
No additional equipment or expertise is required. System gain and zero are also straight-forward front panel adjustments. Gain
may be adjusted at any time, either in AUTO or MANUAL. Setting system ZERO (initial guidepoint) is done by simply placing the
strip at the desired guide position and pressing the ZERO key. (Note: This function is inhibited while the system is in AUTO.) To
avoid tampering, the keyboard may be "locked-out"; a special keystroke sequence re-enables it.
The H6600 is available in several versions, offering automatic detector self-seek and stagger-wind capabilities for recoiling ap-
plications
Along with two detector inputs, connections are provided for a
remote offset signal plus a roll position feedback transducer.
Offset is accomplished through either a conventional analog
potentiometer type (H6220B), or using the unique, digital based,
cascadeable station (H6229).
Remote control is accomplished through 120 V ac inputs for
MANUAL/AUTOMATIC, JOG IN, JOG OUT, ROLL CENTER and
ENABLE. An AC output is available to inhibit a solenoid operated
hydraulic valve as required.
Separate normally open relay contacts are provided to indicate a
system fault condition. A fault condition is either the loss of power,
or inability of the system to gain control within 5 seconds.
The H6600 may be optionally equipped to provide an edge seek-
ing feature for automatic detector positioning. A staggerwind
option is also available.
The 40-character backlit display provides operator feedback
while confi guring the unit plus system status during normal
operations.
DIMENSIONS
inches
(millimeters)
NOTE: ALTERNATE MOUNTING HOLES ARE PROVIDED TO PERMIT COMPATIBILITY
WITH MOUNTING ARRANGEMENTS CREATED FOR EARLIER VERSIONS OF THE
H6600 AND FOR OTHER NORTH AMERICAN PRODUCTS. THE CENTER OF THESE
MOUNTING HOLES ARE LOCATED 14 3 / 4 " (374.7) FROM THE CENTER OF THE UPPER
FLANGE MOUNTING HOLES. THE ALTERNATE MOUNTING HOLES ARE ACCESSED
THROUGH THE FRONT COVER.
DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC.
IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL.
Models: (Add "/2" as a suffi x to designate for 220 V ac operation)
H6600-BFR-01 Standard model
H6600-BFR-02 Man/Auto switch and In-Out spring center switch
on cover
H6600-BFR-03 Same as-02 with added offset pot on cover
H6600-BFR-04 Man/Auto/Servo center switch and In-Out
spring center switch on cover
H6600-BFR-05 Same as-04 with offset pot on the cover
H6600-SS-01 Self-seek motor drive output
H6600-SW-01 Staggerwind control
H6600-SSSW-01 Self-seek motor drive with staggerwind
Power Requirements: 102-132 or 204-264 V ac 50-60 Hz ( max.)
Outputs: Linear Motor Drive (±125 mA)
Remote Meter Drive (±10 V dc)
"C" Solenoid Drive, NO and NC contacts (264 V ac, max.)
Alarm Relay, NO contacts (264 V ac, 2A max.)
SPECIFICATIONS
Inputs: Two independent detector inputs (up to ±15 V dc)
Roll Center/Position feedback (±15 V dc)
Remote Strip Offset Potentiometer (±15 V dc and ±5 V dc)
Operating Temperature Range: 32-122 F (0-50 C)
AC Inputs: Enable
Auto/Manual
Manual Jog IN
Manual Jog OUT
Roll Center
Battery-backed memory: Life expectancy: more than 11 years.
Options: Staggerwind option will accept an encoder input and
stagger the guidepoint at user-selected rates and amplitudes.
Self-seek option will provide AUTOMATIC or MANUAL detector positioning via
additional AC inputs.
Dimensions: 12 1 / 4 "W × 16"H × 4 1 / 2 "D (311 mm × 406 mm × 114 mm)
Weight: 17 lb (8 kg)