99超碰中文字幕在线观看-天天干天天日天天舔婷婷-我看操逼的好看的女人的-日本一二三四五区日韩精品

官方微信|手機版

產(chǎn)品展廳

產(chǎn)品求購企業(yè)資訊會展

發(fā)布詢價單

化工儀器網(wǎng)>產(chǎn)品展廳>分析儀器>色譜>氣相色譜(GC)> 4460623支原體檢測試劑與歧視性陽性對照thermofisher上...

4460623支原體檢測試劑與歧視性陽性對照thermofisher上海精瑞

參考價 18800
訂貨量 ≥1
具體成交價以合同協(xié)議為準

聯(lián)系方式:查看聯(lián)系方式

聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!


 上海精瑞科學儀器有限公司,總部設(shè)在高校云集、學術(shù)氣氛濃郁的上海徐匯區(qū),位處徐家匯-上海體育館繁華商圈,是國內(nèi)色譜分析領(lǐng)域?qū)I(yè)的色譜耗材供應商,色譜耗材專家!有近10萬種產(chǎn)品,同進提供免費色譜柱篩選服務(wù)。       

 

       精瑞科學的專業(yè)及誠信贏得了ThermoFisher、Supelco、Merck、Sigma、BIA Separations等授權(quán)的一級代理。


 我們服務(wù)于醫(yī)藥研發(fā)、生命科學、食品安全、農(nóng)藥、獸藥、環(huán)境、工業(yè)品等檢測領(lǐng)域,與眾多制藥公司、食品企業(yè)、政府檢測機構(gòu)、高??蒲袡C構(gòu)及第三方檢測機構(gòu)都有密切的合作關(guān)系

 

離子色譜耗材,液相色譜耗材,sigma耗材配件,supelco配件耗材

基本信息
數(shù)量:1
用途范圍:1
純度:1%
產(chǎn)地:1
品牌:thermofisher
規(guī)格:1
標記物:1
樣本:1
檢測方法:1
應用:1
檢測限:1
貨號:4460623
是否進口:




MycoSEQ™ Mycoplasma Detection Kit支原體檢測試劑盒

The MycoSEQ™ Mycoplasma Detection Assay, based on real-time PCR and Power SYBR® Green detection technology, is designed for the routine screening and detection of Mycoplasma and other closely related species such as Acholeplasma laidlawii and Spiroplasma citri. Through intensive bioinformatics and highly optimized multiplexed primer design, the system allows for highly sensitive, specific, and comprehensive Mycoplasma species detection. The rapid time-to-results of less than 5 hours supports in-process monitoring for the presence of Mycoplasma during cell culture manufacturing, allowing for the earliest possible detection of a contamination event, and providing protection against the spread of contamination into downstream equipment, processes, and media.

Advantages:
? Rapid time-to-results in less than 5 hours.
? Detection of more than 90 Mycoplasma species.
? Demonstrated sensitivity to detect less than 10 copies?reaction.
? Proven specificity.
? PrepSEQ™ sample preparation for high efficiency DNA recovery.
? Proprietary discriminatory positive?extraction control.
? Externally validated.
? Part of the Cell Culture Rapid Methods Program.

Mycoplasma Detection that Meets European Pharmacopoeia Guidance
Mycoplasmas, the smallest known free living organisms, are relatively common bacterial contaminants of mammalian cell cultures. Potential sources of infection include contaminated raw materials used for cell culture, exposure to contaminated cell cultures, and laboratory staff. Mycoplasmas present particular challenges because they are difficult to detect using traditional microbiological techniques. Figure 1 shows the different points in biopharmaceutical manufacturing where testing for Mycoplasma is typically performed.

Regulatory guidance requires that all products derived from mammalian cell culture be tested for the presence of Mycoplasma. In July 2007, the European Pharmacopoeia (5.8, Sec. 2.6.7) provided guidance on the validation requirements for nucleic acid amplification–based methods for detection of Mycoplasma. Applied Biosystems® designed the MycoSEQ™ Mycoplasma Detection Assay to meet these recommendations.

Detect Mycoplasma in Less than 5 Hours with an Easy-to-Run Assay
The MycoSEQ™ Mycoplasma Detection Assay has a straightforward workflow that can deliver results in less than 5 hours (Figure 2). This rapid time-to-results allows the earliest possible detection of mycoplasma contamination.

These Features Make Performing the Assay Simple:
? Variable test sample volumes, from 100 μl to 10 ml of cell culture containing up to 108 cells.
? Closed-tube, single-step detection.
? Load-and-run, walk-away automation during detection.
? No gel electrophoresis, hybridization, or washing steps.
? Minimal requirements on infrastructure and space.
? Flexible throughput.
? Optimized workflow to provide high sensitivity and specificity during routine testing.

Detect More Than 90 Mycoplasma Species
To help ensure the highest level of confidence in testing for the presence of Mycoplasma, an assay must have the ability to detect all known Mycoplasma species, not just the most common species. Intensive bioinformatics analysis was utilized to design amplification primers and reaction conditions to allow comprehensive detection of known Mycoplasma, Acholeplasma, and Spiroplasma species (Table 1), while avoiding detection of related bacterial species.

Multiparameter Analysis Using Power SYBR® Green Technology
The MycoSEQ™ assay uses highly optimized Power SYBR® Green detection technology, which utilizes multiple parameters, amplification plot (Ct), melting temperature (Tm), and derivative value (D.V.) for interpretation of results. Multiparameter analysis provides highly sensitive and specific detection of fewer than 10 Mycoplasma genome copies per reaction (Figure 3). Numerical readouts for all parameters provide objective test result interpretation.

Discriminatory Positive Control
The MycoSEQ™ Mycoplasma Assay also includes the Discriminatory Positive?Extraction Control, a large plasmid containing a Mycoplasma DNA sequence. This control was designed to behave like Mycoplasma DNA in both the sample preparation and detection portions of the assay. Additionally, the DNA sequence has been modified so that the amplicon generated from this control has a melting temperature (Tm) of approximately 84°C, which is outside the range of amplicons generated from Mycoplasma with this assay. Thus, the Tm can be used to discriminate between a positive test result from Mycoplasma and the control DNA. This novel control enables risk-free DNA spike control testing protocol design, eliminating the possibility of a false positive test result due to accidental cross-contamination of a test sample with the positive control DNA.

您可能感興趣的產(chǎn)品
我要加入


化工儀器網(wǎng)

采購商登錄
記住賬號    找回密碼
沒有賬號?免費注冊

提示

×

*您想獲取產(chǎn)品的資料:

以上可多選,勾選其他,可自行輸入要求

個人信息:

溫馨提示

該企業(yè)已關(guān)閉在線交流功能

屯门区| 武城县| 从化市| 崇礼县| 盐源县| 临澧县| 托克托县| 沙雅县| 罗江县| 门源| 舞阳县| 绥滨县| 沅陵县| 额尔古纳市| 乌兰县| 库伦旗| 安远县| 荥经县| 蒙山县| 金昌市| 扎囊县| 滦平县| 冀州市| 萝北县| 本溪市| 黑河市| 密云县| 河北区| 乌苏市| 来宾市| 二连浩特市| 苗栗县| 新密市| 玉田县| 昌平区| 桂阳县| 临西县| 鄄城县| 云阳县| 靖宇县| 苍山县|